Package | healthdata.be.r4.cbb |
Type | StructureDefinition |
Id | Id |
FHIR Version | R4 |
Source | https://simplifier.net/resolve?scope=healthdata.be.r4.cbb@0.16.0-beta&canonical=https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-VisualAcuity |
Url | https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-VisualAcuity |
Status | draft |
Date | 2022-07-07T09:26:15.1447718+00:00 |
Name | HdBeVisualAcuity |
Title | HdBe-VisualAcuity |
Experimental | False |
Description | Visual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish. #### Purpose The aim is to determine the patient's visual functioning based ontheir visual acuity. #### Patient Populati#### Patient Population children from the age that they can interpret a picture chart. |
Copyright | Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise. |
Type | https://fhir.healthdata.be/StructureDefinition/LogicalModel/VisualAcuity |
Kind | logical |
No resources found
StructureDefinition | |
https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-AnatomicalLocation | HdBe-AnatomicalLocation |
https://fhir.healthdata.be/ValueSet/VisualAcuityMeasurementChart | VisualAcuityMeasurementChart |
https://fhir.healthdata.be/ValueSet/VisualAcuityMeasurementDevice | VisualAcuityMeasurementDevice |
https://fhir.healthdata.be/ValueSet/VisualAcuityType | VisualAcuityType |
{
"resourceType" : "StructureDefinition",
"id" : "HdBe-VisualAcuity",
"language" : "en-US",
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/resource-effectivePeriod",
"valuePeriod" : {
"start" : "2020-09-01T00:00:00+02:00"
}
},
{
"url" : "https://fhir.healthdata.be/StructureDefinition/ext-CBB-MM",
"valueInteger" : 0
}
],
"url" : "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-VisualAcuity",
"name" : "HdBeVisualAcuity",
"_name" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "HdBeVisus"
}
]
}
]
},
"title" : "HdBe-VisualAcuity",
"status" : "draft",
"date" : "2022-07-07T09:26:15.1447718+00:00",
"publisher" : "Healthdata.be (Sciensano)",
"contact" : [
{
"name" : "Service portal â healthdata.be",
"telecom" : [
{
"system" : "url",
"value" : "https://sciensano.service-now.com/sp",
"use" : "work"
}
]
}
],
"description" : "Visual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish.\r\n#### Purpose\r\nThe aim is to determine the patient's visual functioning based ontheir visual acuity.\r\n#### Patient Populati#### Patient Population children from the age that they can interpret a picture chart.",
"_description" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "De visus is een maat voor het gezichtsvermogen (gezichtsscherpte). Het is een maat voor de kleinste details die iemand nog kan onderscheiden.\r\n#### Purpose\r\nHet doel is het bepalen van het visueel functioneren van de patient aan de hand van het gezichtsvermogen. \r\n#### Evidence Base\r\n\r\n\r\n\r\n\r\n**Pa#### Patient Population;\nVolwassenen en kinderen vanaf de leeftijd dat ze een plaatjeskaart kunnen interpreteren. \r\n#### Traceability to other Standards\r\nDeze zorginformatie bouwsteen is gebaseerd op de bouwsteen blauwdruk Meting-v1.0.\r\n"
}
]
}
]
},
"copyright" : "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
"fhirVersion" : "4.0.1",
"kind" : "logical",
"abstract" : true,
"type" : "https://fhir.healthdata.be/StructureDefinition/LogicalModel/VisualAcuity",
"baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Element",
"derivation" : "specialization",
"differential" : {
"element" : [
{
"id" : "VisualAcuity",
"path" : "VisualAcuity",
"short" : "VisualAcuity",
"_short" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "Visus"
}
]
}
]
},
"definition" : "Root concept of the VisualAcuity information model.This root concept contains all data elements of the VisualAcuity information model.",
"_definition" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "Rootconcept van de bouwsteen Visus. Dit rootconcept bevat alle gegevenselementen van de bouwsteen Visus."
}
]
}
]
},
"min" : 0,
"max" : "*"
},
{
"id" : "VisualAcuity.VisualAcuityMeasurementDevice",
"path" : "VisualAcuity.VisualAcuityMeasurementDevice",
"short" : "VisualAcuityMeasurementDevice",
"_short" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "VisusMeetHulpmiddel"
}
]
}
]
},
"definition" : "The device used measuring the visual acuity.",
"_definition" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "Hulpmiddel waarmee de visus is gemeten."
}
]
}
]
},
"min" : 0,
"max" : "1",
"type" : [
{
"code" : "CodeableConcept"
}
],
"binding" : {
"strength" : "extensible",
"description" : "VisualAcuityMeasurementDevice codes",
"valueSet" : "https://fhir.healthdata.be/ValueSet/VisualAcuityMeasurementDevice"
}
},
{
"id" : "VisualAcuity.VisualAcuityType",
"path" : "VisualAcuity.VisualAcuityType",
"short" : "VisualAcuityType",
"_short" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "VisusMetingType"
}
]
}
]
},
"definition" : "Type of visual acuity measurment.",
"_definition" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "Type visus meting."
}
]
}
]
},
"min" : 0,
"max" : "1",
"type" : [
{
"code" : "CodeableConcept"
}
],
"binding" : {
"strength" : "extensible",
"description" : "VisualAcuityType codes",
"valueSet" : "https://fhir.healthdata.be/ValueSet/VisualAcuityType"
}
},
{
"id" : "VisualAcuity.VisualAcuityMeasurementChart",
"path" : "VisualAcuity.VisualAcuityMeasurementChart",
"short" : "VisualAcuityMeasurementChart",
"_short" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "VisusMetingKaart"
}
]
}
]
},
"definition" : "The type of chart used for the visual acuity measurement.",
"_definition" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "Het type kaart dat is gebruikt voor de visus meting."
}
]
}
]
},
"min" : 0,
"max" : "1",
"type" : [
{
"code" : "CodeableConcept"
}
],
"binding" : {
"strength" : "extensible",
"description" : "VisualAcuityMeasurementChart codes",
"valueSet" : "https://fhir.healthdata.be/ValueSet/VisualAcuityMeasurementChart"
}
},
{
"id" : "VisualAcuity.DistanceFromChart",
"path" : "VisualAcuity.DistanceFromChart",
"short" : "DistanceFromChart",
"_short" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "AfstandTotKaart"
}
]
}
]
},
"definition" : "Distance to the chart in meters",
"_definition" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "Afstand tot de kaart in meters."
}
]
}
]
},
"min" : 0,
"max" : "1",
"type" : [
{
"code" : "Quantity"
}
]
},
{
"id" : "VisualAcuity.DecimalVisualAqcuity",
"path" : "VisualAcuity.DecimalVisualAqcuity",
"short" : "DecimalVisualAqcuity",
"_short" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "DecimaleVisusWaarde"
}
]
}
]
},
"definition" : "The measured decimal visual acuity.",
"_definition" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "De gemeten decimale visus."
}
]
}
]
},
"min" : 0,
"max" : "1",
"type" : [
{
"code" : "Quantity"
}
]
},
{
"id" : "VisualAcuity.VisualAcuityDateTime",
"path" : "VisualAcuity.VisualAcuityDateTime",
"short" : "VisualAcuityDateTime",
"_short" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "VisusDatumTijd"
}
]
}
]
},
"definition" : "The date and time when the visual acuity was measured.",
"_definition" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "De datum en tijd waarop de visus is gemeten."
}
]
}
]
},
"min" : 0,
"max" : "1",
"type" : [
{
"code" : "dateTime"
}
]
},
{
"id" : "VisualAcuity.AnatomicalLocation",
"path" : "VisualAcuity.AnatomicalLocation",
"short" : "AnatomicalLocation",
"_short" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "AnatomischeLocatie"
}
]
}
]
},
"definition" : "The laterality of the eye of which the visual acuity has been measured.",
"_definition" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/translation",
"extension" : [
{
"url" : "lang",
"valueCode" : "nl-BE"
},
{
"url" : "content",
"valueMarkdown" : "De zijdigheid van het oog waarvan de visus is gemeten."
}
]
}
]
},
"min" : 0,
"max" : "1",
"type" : [
{
"code" : "AnatomicalLocation",
"profile" : [
"https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-AnatomicalLocation"
]
}
]
}
]
},
"text" : {
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.